Product

Product

10kV oil immersed transformer

  Reliable structure  1.Spiral coil with longitudinal oil passage for better internal heat dissipation;  2.Improved the effective support of the coil end face,with stronger resistance to short-circuit current;  3.New lifting and positioning structures have been adopted to ensure greater reliability during long-distance transportation and operation;  4.We have many unique and reliable structures to serve you;  5.Choosing transformers with higher performance levels will result in higher levels of technological content.  Excellent materials  Choose oxygen free copper wire with lower resistivity and undergo a series of additional surface treatments to make it smoother,without burrs or sharp corners,resulting in lower load loss and more reliable electrical performance of the transformer.  Select high-quality silicon steel sheets,and with the improvement of performance level,use silicon steel sheets with lower unit loss to reduce the no-load loss of transformers.  Select high-quality laminated wood insulation components that will never crack,even under the action of short-circuit current,and remain intact.  Using transformer oil that has undergone deep filtration results in lower levels of water,gas,and impurities,making transformer operation more reliable.  Select excellent rubber sealing materials to effectively prevent aging and eliminate leakage.  All raw materials undergo quality inspection,effectively preventing aging and eliminating leakage.  All raw materials undergo quality inspection,and all raw material manufacturers undergo strict review in accordance with the national standard ISO9000.  Good technical and economic performance  On the basis of the S9 series,the S11 series products have reduced the average no-load loss by 30%;The no-load current decreases by 70-85%compared to S9;The average temperature rise is reduced by 10K,and the product's service life is more than doubled.Even under overload conditions of 20%,it can still operate for a long time;The average noise reduction during product operation is 2-4 decibels.  Fully sealed  The M in S11(M)R indicates that the oil tank adopts a fully sealed structure.Compared with ordinary oil immersed transformers,fully sealed distribution transformers eliminate oil storage tanks and replace oil pipes with wave fins as cooling and heat dissipation components.The wave fins of the oil tank are manufactured from high-quality cold-rolled thin plates on a dedicated production line.The wave fins can expand and contract the volume of transformer oil,thereby isolating the transformer from the atmosphere,preventing and slowing down oil degradation and insulation moisture,enhancing operational reliability,and maintenance free normal operation.  The surface of the corrugated oil tank is treated with degreasing,rust removal,and phosphating before being coated with a three proof paint,which is suitable for use in metallurgical,petrochemical,mining,and other environments.  Transformer product standards  GB 1094.1-1996 GB 1094.2-1996 JB/T10088-2004  GB 1094.3-2003 GB 1094.5-2003 GB/T 10237-1988  GB/T 6451-2008 GB/T 7595-1987 JB/T 3837-2010  Transformer usage conditions  Normal usage conditions  Altitude not exceeding 1000m;  Environmental temperature:  Maximum temperature+40℃  The average temperature of the hottest month is+30℃  The highest annual average temperature is+20℃  Outdoor minimum temperature-25℃  Special operating conditions for transformers(detailed instructions at the time of ordering)  Altitude exceeding 1000m;  Environmental temperature:  Maximum temperature+40℃  Minimum temperature-25℃

More +

20kV oil immersed transformer

  Reliable structure  1.Spiral coil with longitudinal oil passage for better internal heat dissipation;  2.Improved the effective support of the coil end face,with stronger resistance to short-circuit current;  3.New lifting and positioning structures have been adopted to ensure greater reliability during long-distance transportation and operation;  4.We have many unique and reliable structures to serve you;  5.Choosing transformers with higher performance levels will result in higher levels of technological content.  Excellent materials  Choose oxygen free copper wire with lower resistivity and undergo a series of additional surface treatments to make it smoother,without burrs or sharp corners,resulting in lower load loss and more reliable electrical performance of the transformer.  Select high-quality silicon steel sheets,and with the improvement of performance level,use silicon steel sheets with lower unit loss to reduce the no-load loss of transformers.  Select high-quality laminated wood insulation components that will never crack,even under the action of short-circuit current,and remain intact.  Using transformer oil that has undergone deep filtration results in lower levels of water,gas,and impurities,making transformer operation more reliable.  Select excellent rubber sealing materials to effectively prevent aging and eliminate leakage.  All raw materials undergo quality inspection,effectively preventing aging and eliminating leakage.  All raw materials undergo quality inspection,and all raw material manufacturers undergo strict review in accordance with the national standard ISO9000.  Good technical and economic performance  On the basis of the S9 series,the S11 series products have reduced the average no-load loss by 30%;The no-load current decreases by 70-85%compared to S9;The average temperature rise is reduced by 10K,and the product's service life is more than doubled.Even under overload conditions of 20%,it can still operate for a long time;The average noise reduction during product operation is 2-4 decibels.  Fully sealed  The M in S11(M)R indicates that the oil tank adopts a fully sealed structure.Compared with ordinary oil immersed transformers,fully sealed distribution transformers eliminate oil storage tanks and replace oil pipes with wave fins as cooling and heat dissipation components.The wave fins of the oil tank are manufactured from high-quality cold-rolled thin plates on a dedicated production line.The wave fins can expand and contract the volume of transformer oil,thereby isolating the transformer from the atmosphere,preventing and slowing down oil degradation and insulation moisture,enhancing operational reliability,and maintenance free normal operation.  The surface of the corrugated oil tank is treated with degreasing,rust removal,and phosphating before being coated with a three proof paint,which is suitable for use in metallurgical,petrochemical,mining,and other environments.  Transformer product standards  GB 1094.1-1996 GB 1094.2-1996 JB/T10088-2004  GB 1094.3-2003 GB 1094.5-2003 GB/T 10237-1988  GB/T 6451-2008 GB/T 7595-1987 JB/T 3837-2010  Transformer usage conditions  Normal usage conditions  Altitude not exceeding 1000m;  Environmental temperature:  Maximum temperature+40℃  The average temperature of the hottest month is+30℃  The highest annual average temperature is+20℃  Outdoor minimum temperature-25℃  Special operating conditions for transformers(detailed instructions at the time of ordering)  Altitude exceeding 1000m;  Environmental temperature:  Maximum temperature+40℃  Minimum temperature-25℃

More +

35kV oil immersed transformer

  Reliable structure  1.Spiral coil with longitudinal oil passage for better internal heat dissipation;  2.Improved the effective support of the coil end face,with stronger resistance to short-circuit current;  3.New lifting and positioning structures have been adopted to ensure greater reliability during long-distance transportation and operation;  4.We have many unique and reliable structures to serve you;  5.Choosing transformers with higher performance levels will result in higher levels of technological content.  Excellent materials  Choose oxygen free copper wire with lower resistivity and undergo a series of additional surface treatments to make it smoother,without burrs or sharp corners,resulting in lower load loss and more reliable electrical performance of the transformer.  Select high-quality silicon steel sheets,and with the improvement of performance level,use silicon steel sheets with lower unit loss to reduce the no-load loss of transformers.  Select high-quality laminated wood insulation components that will never crack,even under the action of short-circuit current,and remain intact.  Using transformer oil that has undergone deep filtration results in lower levels of water,gas,and impurities,making transformer operation more reliable.  Select excellent rubber sealing materials to effectively prevent aging and eliminate leakage.  All raw materials undergo quality inspection,effectively preventing aging and eliminating leakage.  All raw materials undergo quality inspection,and all raw material manufacturers undergo strict review in accordance with the national standard ISO9000.  Good technical and economic performance  On the basis of the S9 series,the S11 series products have reduced the average no-load loss by 30%;The no-load current decreases by 70-85%compared to S9;The average temperature rise is reduced by 10K,and the product's service life is more than doubled.Even under overload conditions of 20%,it can still operate for a long time;The average noise reduction during product operation is 2-4 decibels.  Fully sealed  The M in S11(M)R indicates that the oil tank adopts a fully sealed structure.Compared with ordinary oil immersed transformers,fully sealed distribution transformers eliminate oil storage tanks and replace oil pipes with wave fins as cooling and heat dissipation components.The wave fins of the oil tank are manufactured from high-quality cold-rolled thin plates on a dedicated production line.The wave fins can expand and contract the volume of transformer oil,thereby isolating the transformer from the atmosphere,preventing and slowing down oil degradation and insulation moisture,enhancing operational reliability,and maintenance free normal operation.  The surface of the corrugated oil tank is treated with degreasing,rust removal,and phosphating before being coated with a three proof paint,which is suitable for use in metallurgical,petrochemical,mining,and other environments.  Transformer product standards  GB 1094.1-1996 GB 1094.2-1996 JB/T10088-2004  GB 1094.3-2003 GB 1094.5-2003 GB/T 10237-1988  GB/T 6451-2008 GB/T 7595-1987 JB/T 3837-2010  Transformer usage conditions  Normal usage conditions  Altitude not exceeding 1000m;  Environmental temperature:  Maximum temperature+40℃  The average temperature of the hottest month is+30℃  The highest annual average temperature is+20℃  Outdoor minimum temperature-25℃  Special operating conditions for transformers(detailed instructions at the time of ordering)  Altitude exceeding 1000m;  Environmental temperature:  Maximum temperature+40℃  Minimum temperature-25℃

More +

Compact substation

  The Xinghe brand YB series box type substation is mainly composed of multiple circuit high-voltage switch systems,armored busbars,substation comprehensive automation systems,communication,remote control,metering,capacitor compensation,and DC power supply electrical units.It is installed in a moisture-proof,rust proof,dust-proof,rodent proof,fireproof,anti-theft,heat-insulating,fully enclosed,and movable steel structure box,with electromechanical integration and fully enclosed operation.  Product Features  1.Advanced technology,safe and reliable,integrating high-voltage switchgear,transformers,and low-voltage switchgear,with strong completeness  2.Factory prefabrication allows designers to choose the specifications and models of the transformer provided by the manufacturer as long as they make a main wiring diagram and design the equipment outside the box according to the actual requirements of the substation,  3.High degree of automation;Complete high and low voltage protection,safe and reliable operation,and simple maintenance  4.Small footprint,low investment,short production cycle,easy mobility,flexible and diverse wiring solutions  5.Small footprint and unique structure:The unique honeycomb structure double-layer(composite plate)shell is firm,insulated,ventilated,beautiful,and has a high level of protection.The shell materials include stainless steel alloy,aluminum alloy,cold-rolled plate,and color steel plate to choose from  6.Beautiful appearance,diverse styles:universal,villa,compact,and other styles;  7.The high-voltage ring main unit can be equipped with a network automation terminal(FTU)to achieve reliable detection of short circuits and single-phase grounding faults,with the"four remote"function,which facilitates the upgrade of distribution network automation

More +

Scott Transformer

  The transformer connected by Scott is usually composed of two single-phase transformers.Connecting the end of a transformer's high-voltage winding to the center of another high-voltage winding can form a three-phase high-voltage winding with a T-shaped structure.Each low-voltage winding is a simple single-phase winding with no electrical connection between them.Their voltage and current are the same as those of ordinary single-phase transformers.But the winding and current of each high-voltage group are different from those of ordinary single-phase transformers.  Every part and port of a transformer needs to be wired,and various wiring methods and techniques have an impact on the operation of the transformer itself.Once the transformer's wiring is connected incorrectly,it will affect the effectiveness of using the transformer and pose a safety hazard,resulting in unimaginable consequences.The fundamental safety of transformers and the operation of wiring must be approached with utmost caution,with correct and standardized operation being essential  Technical parameters:  Exterior structure:Vertical  Cooling method:natural cooling  Moisture proof method:open type  Number of windings:Double winding  Iron core structure:shell type  Cooling method:dry type  Iron core shape:EI type  Number of power phases:Three phase  Frequency characteristics:low frequency  Model:SDG-100/0.38  Application scope:Special

More +

Photovoltaic specialized transformer

  With the advancement of global energy structure transformation,renewable energy has gradually become a development focus in the energy sector.Photovoltaic power generation,as an important renewable energy source,plays an increasingly important role in the power system.In the photovoltaic power generation system,the step-up transformer is a crucial component,and its performance and reliability directly affect the stability and efficiency of the entire system.This article will provide a detailed explanation of the structure,characteristics,applications,and selection of photovoltaic step-up transformers.  Photovoltaic step-up transformer is a key equipment used in photovoltaic power generation systems to boost low voltage level electrical energy to high voltage level.Its structure is similar to that of a regular power transformer,consisting of iron core,winding,insulation material,and heat dissipation system.However,in the design and manufacturing process of photovoltaic step-up transformers,some special factors need to be considered,such as high temperature,high humidity,high altitude,high lightning strikes and other harsh environmental conditions,as well as lightning protection,overload protection and other functions.  Product features:  1.High reliability:Due to the fact that photovoltaic power generation systems are generally located in remote areas and operate in harsh environments,it is required that the step-up transformer has high reliability and durability,and can operate stably in extreme environments.  2.High efficiency:As an energy conversion device,the step-up transformer should have a high conversion efficiency to reduce energy loss and equipment heating.  3.Strong adaptability:The step-up transformer in the photovoltaic power generation system needs to adapt to different operating requirements and environmental conditions.For example,for power stations with different geographical locations and climatic conditions,step-up transformers should be able to be flexibly configured to meet different capacity requirements,voltage levels,and insulation levels.  4.Environmental protection and energy conservation:With the increasing awareness of environmental protection,the design of step-up transformers should also pay attention to environmental protection and energy conservation,such as using low loss materials,optimizing structural design,and other measures to reduce energy consumption and noise pollution.  Application of photovoltaic step-up transformers in photovoltaic power generation systems:  1.Centralized photovoltaic power generation system:In a centralized photovoltaic power generation system,due to the low power output of solar panels,multiple step-up transformers are required to boost the electrical energy to a high voltage level,and then transmit it to the power system through transmission lines.  2.Distributed photovoltaic power generation system:In a distributed photovoltaic power generation system,due to the placement of solar panels on the roof or ground of buildings,which are close to the load center,electrical energy can be directly sent to the low-voltage distribution system without the need for a step-up transformer.  3.Energy storage photovoltaic power generation system:In the energy storage photovoltaic power generation system,since the charging and discharging of the energy storage battery need to be completed in a short time,the electrical energy needs to be quickly boosted to a high voltage level through a step-up transformer to reduce the impact of charging and discharging currents on battery performance.  The selection of photovoltaic step-up transformers needs to consider the following factors:  1.Capacity:The capacity of the step-up transformer is determined based on factors such as the installed capacity of the photovoltaic power generation system,power demand,and power transmission distance.In general,the capacity of the step-up transformer should be slightly greater than the output power of the solar panel.  2.Voltage level:Select the voltage level of the step-up transformer according to the requirements of the output voltage level of the photovoltaic power generation system.In general,the voltage level of the step-up transformer should match the output voltage level of the solar panel.  3.Loss:When choosing a step-up transformer,attention should be paid to its energy efficiency indicators and loss situation.Choosing low loss and high-efficiency step-up transformers can reduce operating costs and improve system efficiency.  4.Protection level:As photovoltaic power generation systems are generally located in harsh environments,it is required that the step-up transformer has a high protection level to cope with harsh environmental conditions such as high temperature,high humidity,high altitude,and high lightning strikes.  In summary,as one of the key equipment in photovoltaic power generation systems,the performance and reliability of photovoltaic step-up transformers directly affect the stability and efficiency of the entire system.When selecting and applying photovoltaic step-up transformers,factors such as their structural characteristics,application scenarios,and selection requirements should be fully considered to ensure the normal operation of the system and maximize its benefits.Meanwhile,with the continuous advancement and development of technology,the performance and reliability of photovoltaic step-up transformers will be further improved and perfected,providing stronger support for the future development of renewable energy.

More +

High overload transformer

  A high overload transformer is a specially designed power equipment that primarily converts high voltage electrical energy into low voltage electrical energy to meet the needs of different power applications.It can provide higher current output and meet the requirements of high-power equipment.  High overload transformers have some unique characteristics in design and manufacturing compared to ordinary transformers.  1.High load capacity  Compared to ordinary transformers,high overload transformers have higher load capacity.In high-power equipment application scenarios,high overload transformers can withstand larger loads,provide stable current output,and ensure the normal operation of equipment  2.Stable voltage conversion  Through precise design and manufacturing,high overload transformers can maintain high stability during voltage conversion,provide accurate output voltage,and ensure that electrical equipment will not be damaged due to voltage fluctuations during operation.  3.Energy saving  High overload transformers adopt advanced magnetic circuit design and high-performance materials,which have high energy efficiency and can effectively reduce energy loss.Compared with traditional transformers,high overload transformers can provide more energy-saving and environmentally friendly power conversion solutions  4.Safe and reliable  As a reliable manufacturer of high overload transformers,Huawei strictly adheres to international standards and safety regulations to ensure product quality,safety,and reliability.The product has undergone rigorous testing and experimentation,and is capable of long-term stable operation under various environmental conditions  High overload transformers are essential equipment in modern power systems.They are not only a key link in energy conversion,but also provide stable current output and high-efficiency conversion solutions.

More +
12 共18条 2页,到第 确定

QR code

Contact

Mobile:132-3379-5088

Tel:0379-66300985

Email:xhtb@xinghetb.com

Address:Industrial Development Zone, Chengguan Town, Song County, Luoyang City

132-3379-5088